Footwear Slip Resistance Testing: Methods, Equipment, and Standards

Footwear slip resistance testing evaluates how effectively a shoe’s outsole interacts with a floor surface under controlled conditions. For footwear manufacturers, product developers, and quality teams, these tests provide measurable information about friction and relative slip performance.

However, slip resistance does not depend on outsole material alone. Tread geometry, floor type, surface contaminants, and testing conditions can all influence the result. Therefore, manufacturers need to select an appropriate test method and interpret its results in the context of the footwear’s intended use.

Several standards address this performance characteristic, including ASTM F2913-24, ASTM F3445-24, SATRA TM144, and ISO 13287:2019. Understanding their different purposes helps buyers and manufacturers establish relevant testing requirements.

What Is Footwear Slip Resistance Testing?

Footwear slip resistance testing measures the friction between a shoe’s outsole and a floor surface. It helps evaluate how the footwear responds when the two surfaces make contact and move relative to each other.

Friction plays an important role in walking. When the available friction between a shoe and the floor cannot meet the demands of a walking movement, the shoe may begin to slide. A suitable outsole design can help reduce this risk under the conditions for which the footwear was developed.

However, no single material or tread pattern guarantees the same performance on every floor. A shoe may behave differently on dry tile, wet concrete, oily flooring, or other surfaces.

What Does the Test Measure?

Many footwear slip resistance methods measure the coefficient of friction (COF). This value describes the relationship between the frictional force and the normal force pressing two surfaces together.

Dynamic coefficient of friction (DCOF) refers specifically to friction during relative movement between surfaces. In a typical test, the equipment measures the horizontal frictional force while controlling the contact load and movement.

A simplified relationship is:

DCOF = Horizontal frictional force ÷ Normal force

A higher DCOF generally indicates greater measured friction under the particular test conditions. However, it does not establish a universal slip-resistant rating. The test method, surface, contaminant, and applicable performance criteria all matter.

Whole-Shoe Testing vs. Outsole Testing

Testing a complete shoe evaluates the interaction between the assembled footwear and the test floor. The shoe’s geometry, heel and forepart contact, outsole construction, and tread design can all influence the result.

By comparison, testing an outsole unit or sole material focuses on a component rather than the complete footwear product. This approach can help developers compare materials or design alternatives during product development.

ASTM F2913 and SATRA TM144 cover whole footwear as well as certain soling components. Nevertheless, the test specimen and setup must follow the selected method.

How Is Footwear Slip Resistance Tested?

The exact procedure depends on the standard and equipment. In general, laboratory testing follows a controlled sequence to make results more consistent and suitable for comparison.

A typical whole-shoe testing process includes:

  1. Select the footwear sample. Identify the shoe style, size, outsole construction, and relevant product details.
  2. Prepare the test surface. Select the specified flooring material and prepare it according to the test method.
  3. Apply the required surface condition. Depending on the test, the floor may remain dry or receive a specified contaminant, such as water or oil.
  4. Position the footwear. Mount or position the shoe so the required outsole area contacts the test surface.
  5. Apply the prescribed load and movement. The equipment controls the contact force, movement direction, and speed.
  6. Measure frictional force. Sensors record the horizontal force generated as the footwear moves relative to the floor.
  7. Calculate and record DCOF. The equipment calculates the coefficient of friction under the specified conditions.
  8. Evaluate the results. Compare the findings with the applicable standard or buyer-defined performance requirements.

The exact load, contact angle, movement speed, timing, and surface preparation are not universal. Laboratories must follow the selected standard rather than combine parameters from different methods.

For a broader overview of laboratory evaluations, see FUYU’s guide to footwear testing methods.

ASTM F2913 vs. ASTM F3445: What’s the Difference?

ASTM F2913-24 and ASTM F3445-24 work together, but they serve different purposes. One defines a test method; the other establishes performance requirements for footwear evaluated using that method.

ComparisonASTM F2913-24ASTM F3445-24
Document typeTest methodPerformance specification
Main purposeMeasures coefficient of frictionSpecifies minimum slip resistance performance requirements
Testing approachUses a whole-shoe testerUses results from the ASTM F2913 whole-shoe tester
Main applicationFootwear and relevant soling materialsCompleted footwear
Key questionHow is friction measured?What performance requirement must footwear meet?

ASTM F2913-24: Footwear Slip Resistance Test Method

The full title of ASTM F2913-24 is Standard Test Method for Measuring the Coefficient of Friction for Evaluation of Slip Performance of Footwear and Test Surfaces/Flooring Using a Whole Shoe Tester.

Published by ASTM International, this method determines the dynamic coefficient of friction between footwear and flooring under reproducible laboratory conditions.

Its scope includes:

  • Complete footwear
  • Outsole units
  • Heel top lifts
  • Sheet soling materials
  • Different flooring surfaces
  • Surface contaminants, including water, ice, oil, and grease

The method supports relative slip performance evaluation. By controlling the test conditions, laboratories can compare footwear samples and examine how different outsole designs or surfaces affect measured friction.

Importantly, ASTM F2913 does not establish that a shoe will perform identically in every workplace. Its results apply to the conditions used during testing.

See the official ASTM F2913-24 standard for its scope and technical requirements.

ASTM F3445-24: Slip Resistance Performance Requirements

ASTM F3445-24 is titled Standard Specification for Performance Requirements when Evaluating Slip Resistance of Footwear using ASTM F2913 Whole Shoe Tester.

Unlike F2913, F3445 is a performance specification. It establishes minimum slip resistance requirements for completed footwear when evaluated using the ASTM F2913 whole-shoe tester.

The distinction is important for manufacturers and buyers:

  • ASTM F2913-24 explains how to measure friction under controlled conditions.
  • ASTM F3445-24 specifies the minimum performance requirements for footwear evaluated using that test method.

F3445 is not a separate testing machine or an alternative friction measurement procedure. It relies on the F2913 whole-shoe testing approach.

The ASTM specification also makes clear that controlled laboratory results do not establish performance for every situation a wearer may encounter. Where specific workplace hazards exist, the selected flooring and contaminants should reflect those conditions as closely as the applicable method allows.

Consult the official ASTM F3445-24 specification before defining acceptance requirements. Do not assume that a result from another test method automatically demonstrates compliance with F3445.

Other Footwear Slip Resistance Testing Standards

ASTM is not the only organization with relevant footwear friction test methods. SATRA TM144 and ISO 13287 also address slip resistance, although their scope and procedures differ.

SATRA TM144

SATRA TM144, Friction (Slip Resistance) of Footwear and Floorings, determines the coefficient of friction between footwear and test floors under conditions intended to represent phases of a typical walking step when slipping is likely.

The method applies to complete footwear and several types of soling components. It also accommodates different test floors and surface conditions, including ice, turf, gravel, water, oil, and grease.

During testing, the footwear and floor make contact under a specified vertical force. The equipment then moves the surfaces horizontally relative to each other at a controlled speed. It measures the frictional force and calculates the dynamic coefficient of friction.

SATRA TM144 and ASTM F2913 share the goal of evaluating footwear friction, but their procedures and specified conditions are not automatically interchangeable. A buyer should identify the required method before commissioning a test.

See SATRA TM144 for its scope and method description.

EN ISO 13287:2019

ISO 13287:2019 is titled Personal protective equipment — Footwear — Test method for slip resistance.

Its scope specifically addresses slip resistance testing of personal protective equipment (PPE) footwear. It should not be presented as a universal requirement for all ordinary footwear, such as casual slippers or sandals.

The standard also notes that laboratories may test sole units, outsoles, and other soling components for product development purposes.

Manufacturers should distinguish between using a method to compare sole designs during development and claiming that completed footwear meets a PPE-related requirement.

Refer to the official ISO 13287:2019 page for the current publication and scope information.

Footwear Slip Resistance Testing Equipment

Laboratories use specialized equipment to control contact force, movement, and friction measurement. The configuration must match the selected test method.

A typical whole-shoe slip resistance testing system includes:

  • Whole-shoe tester: Holds or positions the footwear and controls its contact with the test surface.
  • Test flooring: Provides the specified surface material, such as ceramic tile or another defined floor type.
  • Loading system: Applies the required vertical force during contact.
  • Movement system: Controls the relative movement between the footwear and floor.
  • Force measurement system: Records horizontal frictional force and other relevant test data.
  • Data acquisition software: Processes measurements and calculates friction values.

Equipment calibration and control of test conditions are essential. Changes in surface condition, loading, speed, or equipment setup can affect measured results.

SATRA STM 603 as an Equipment Example

The SATRA STM 603 is a commercially available footwear slip resistance tester. SATRA developed it to reproduce aspects of walking biomechanics, including the contact conditions associated with heel strike and toe lift.

The machine can evaluate complete footwear and suitable sole components against different floor surfaces. Its system controls relevant test forces and movement while recording data for coefficient of friction calculations.

SATRA identifies TM144 and EN ISO 13287 among the test programs available for the equipment. However, owning a particular machine does not automatically establish compliance with every slip resistance standard. The laboratory must use the appropriate configuration, procedure, and acceptance criteria.

Read SATRA’s overview of the STM 603 slip resistance testing machine for more information.

How to Interpret Footwear Slip Resistance Test Results

A test result should always be read together with its testing conditions. A DCOF value without the relevant method and surface information provides limited insight into actual footwear performance.

When reviewing a laboratory report, check the following details:

  • Test standard and version: Confirm whether the laboratory used ASTM F2913, SATRA TM144, ISO 13287, or another specified method.
  • Test specimen: Identify whether the laboratory tested complete footwear, an outsole unit, or a material sample.
  • Flooring material: Check the type and condition of the test surface.
  • Contaminant: Determine whether the test used dry, wet, oily, or another specified condition.
  • Contact area and direction: Review the relevant outsole area and test orientation.
  • Measured results: Examine the reported DCOF values and any separate results for different test conditions.
  • Performance criteria: Check whether the results meet the requirements of the applicable specification.

Is There a Universal Shoe Slip Resistance Rating?

No single DCOF value provides a universal rating for every shoe and floor condition. A result must be interpreted according to the test method and relevant performance specification.

For example, a footwear sample may produce different friction values on dry flooring and on a wet or contaminated surface. A high value under one condition does not guarantee equally strong performance under another.

Therefore, buyers should request the complete test report rather than rely on an isolated friction value or an unexplained “slip-resistant” label.

Factors That Affect Footwear Slip Resistance

Several design and environmental factors influence the interaction between an outsole and a floor.

Outsole Material

Rubber, EVA, PVC, and other sole materials can produce different friction behavior. However, no material is automatically the most slip-resistant in every application.

Formulation, hardness, surface texture, processing, and contact conditions can all affect the result. Even two EVA soles may behave differently because their formulations and surface designs differ.

For more information about the material, see FUYU’s guide to EVA sole material.

Outsole Tread Pattern

Tread geometry affects how the outsole contacts the floor. Grooves, channels, contact areas, and surface patterns can influence friction and the movement of contaminants.

On wet surfaces, for example, suitable channels may help move liquid away from contact areas. However, the effectiveness of a tread pattern depends on its design and the conditions in which the footwear operates.

Floor Surface and Contaminants

Different floors can produce different friction results. Ceramic tile, concrete, metal, and other surfaces have different textures and surface characteristics.

Contaminants can also change the interaction. Water, oil, grease, and cleaning residues may reduce available friction or alter how the outsole contacts the floor.

SATRA’s discussion of footwear for food preparation areas illustrates why test surfaces and contaminants should reflect the intended working environment.

Footwear Construction and Wear

The complete outsole construction matters, not just the material. Sole geometry, heel and forepart contact, tread depth, and component alignment may affect the test result.

Wear can also change outsole surface characteristics and tread geometry over time. Consequently, a test performed on new footwear does not necessarily represent the performance of a heavily worn product.

Why Footwear Slip Resistance Testing Matters for Manufacturers

Slip resistance testing gives manufacturers useful information during product development and quality evaluation. It helps teams compare outsole designs, examine material combinations, and check whether a finished product meets specified performance requirements.

For manufacturers, testing can support several activities:

  • Product development: Compare outsole materials, tread patterns, and construction options.
  • Design evaluation: Identify how changes in outsole geometry influence measured friction.
  • Quality control: Check whether selected samples meet defined performance requirements.
  • Customer specifications: Provide test evidence when buyers request documented slip resistance results.
  • Product documentation: Maintain records of test methods, conditions, and measured performance.

The appropriate testing plan depends on the product’s intended use. Ordinary EVA slippers, EVA sandals, garden shoes, and PVC slippers do not automatically fall under the same requirements as occupational protective footwear.

For FUYU, a Jinjiang-based footwear manufacturer established in 2007, outsole design and material selection are relevant considerations across its EVA and PVC footwear products. Clear product specifications help manufacturers and OEM/ODM buyers identify which performance characteristics matter and determine whether additional testing is necessary.

Frequently Asked Questions

What Is the Standard Test for Footwear Slip Resistance?

The appropriate method depends on the footwear category, intended use, and buyer requirements. ASTM F2913 measures footwear-floor friction, ASTM F3445 specifies performance requirements using the F2913 whole-shoe tester, SATRA TM144 evaluates footwear and flooring friction, and ISO 13287 addresses PPE footwear.

What Is the Difference Between ASTM F2913 and ASTM F3445?

ASTM F2913 is a test method that measures the dynamic coefficient of friction between footwear and flooring. ASTM F3445 is a performance specification that establishes minimum slip resistance requirements for completed footwear evaluated using the F2913 whole-shoe tester.

How Do You Test Slip-Resistant Shoes?

A laboratory positions the footwear against a specified test surface, applies a controlled load, and moves the footwear relative to the floor under defined conditions. The equipment measures frictional force and calculates DCOF. Exact parameters depend on the selected standard.

What Does a Shoe Slip Resistance Rating Mean?

A slip resistance result indicates how the footwear performed under specific test conditions. Buyers should review the test method, flooring, contaminant, specimen type, measured DCOF, and applicable performance requirements before interpreting the result.

Does EVA Make a Shoe Slip-Resistant?

No. EVA alone does not guarantee slip resistance. Formulation, outsole geometry, tread pattern, surface condition, and the interaction with the floor all influence performance. Testing is necessary when a defined slip resistance requirement applies.

Can Slip Resistance Testing Guarantee That Shoes Will Never Slip?

No laboratory test can guarantee slip-free performance in every real-world situation. Actual conditions may differ from the test environment, and flooring, contaminants, footwear wear, and walking behavior can all affect slipping risk.

Conclusion

Footwear slip resistance testing helps manufacturers and buyers evaluate outsole performance under controlled conditions. Understanding the difference between ASTM F2913-24 and ASTM F3445-24 is particularly important: one measures friction, while the other defines performance requirements using that test method.

By selecting an appropriate standard, controlling test conditions, and reviewing complete laboratory results, footwear teams can make better-informed decisions about outsole materials and product design. These steps also help manufacturers align product development with the actual requirements of their customers and target markets.

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *